Verified Device Catalog: Ingestion Scope and Limits
easyeda_catalog_verify_device resolves an LCSC part number into a catalog device entry (src/catalog/schema.ts) and caches it locally (easyeda_catalog_list reads that cache back). This page states plainly what it can and cannot verify, because the name "verify" is easy to over-read.
What this pipeline actually does
It combines two independent, best-effort sources:
- The keyless LCSC tier (
src/vendors/lcsc/client.ts) — manufacturer/MPN string, package description, stock, price, and basic/preferred/extended classification. This is commodity metadata only. library.getDeviceByLcscId, a bridge method backed by EasyEDA Pro's real, typed (@beta)LIB_Device.getByLcscIdsAPI — a reference (name + UUID) to a symbol and footprint, but only when the part is already known to the connected EasyEDA Pro instance's own library. This method is also documented as unavailable in private-deployment environments.
What it cannot do, and why
There is no available API — keyless LCSC or EasyEDA Pro's documented surface — that returns real pin/pad geometry for an arbitrary LCSC part number. Concretely:
- jlcsearch (the keyless tier) never returns pin lists, pad counts, or a parsed datasheet — its
packagefield is a free-text description like"0603"or"QFN-28", not a footprint definition. LIB_Device.getByLcscIdsreturns library UUID references to a symbol/footprint — not their drawn content. NeitherLIB_SymbolnorLIB_Footprintin EasyEDA Pro's API exposes a read method for the underlying drawing; the only related methods areupdateDocumentSource(write-only) andgetRenderImage(a bitmap image, not structured geometry).courtyardis not a modeled concept anywhere in EasyEDA Pro's typed API.
So this pipeline cannot and does not attempt to:
- Fetch or verify pad geometry, pad count, or pin-to-pad correspondence.
- Check for courtyard presence or footprint/pin-map consistency.
- Ingest a symbol/footprint for a part that is not already in the connected EasyEDA Pro instance's library — it can only find a reference to one that already exists.
If a future data source changes this (e.g. an official LCSC symbol/footprint export API, or a datasheet-parsing pipeline), these gates should be added to src/catalog/validation.ts rather than assumed here.
Status vocabulary
easyeda_catalog_verify_device reports one of three statuses:
| Status | Meaning |
|---|---|
resolved | A real EasyEDA library match was found and the entry passes catalog validation. |
partial | A real EasyEDA library match was found, but validation still fails (e.g. no pin map, see above). |
unresolved | No EasyEDA library match was found; symbolRef/footprintRef are placeholder markers (UNRESOLVED:<lcsc-id>), which validation always flags as an error for categories that require a real symbol/footprint. |
A resolved status means the symbol/footprint reference and commodity metadata were found and the entry is internally consistent — not that the pin mapping or footprint is complete or manufacturable. Treat every ingested device as a starting point for human review, the same way docs/vendor-terms.md treats all supplier data as advisory.
Storage
Verified devices are cached in the local SQLite database (verified_devices table, src/storage/database.ts) under the user's own SQLITE_PATH — never committed to the repository or redistributed, consistent with docs/vendor-terms.md rule 4.
Using resolved devices in circuit planning
src/circuit/component-planning.ts's planComponents() accepts an optional pre-loaded catalog ({ catalog: DeviceEntry[] }) and will fill in mpn/manufacturer/package/lcsc for a high-confidence component role when a matching, non-obsolete catalog device exists, setting planningState to resolved instead of candidate. This is opt-in and additive — omitting the option preserves the original role/refdes/package-hint-only behavior. When no match exists, the plan result includes a warning suggesting easyeda_catalog_verify_device for a candidate LCSC part number.