Historical engineering experiment (October 2026). This page records an earlier local-only investigation, not the current publication, validation or manufacturing status. The original no-GitHub-change statements describe the experiment at that time; its source was later included in the recovery integration PR. No fabrication approval is implied.

This is a SOURCE-BOUND unrouted KiCad placement experiment. It is not production approval, physical-device signoff, a release or a GitHub update.

Verified problem

The initial 12-component / 8-net source-bound KiCad 10.0.7 board had 42 unconnected items and 445 other DRC findings, including 9 shorting, 277 clearance and 131 solder-mask bridge violations. Every short, all 277 clearance findings and all 131 mask bridges occurred on U2 STM32. The older generic footprint resolver had placed 48 LQFP leads along incompatible temporary pad geometry, causing overlapping copper and mask.

Bounded correction in a derived placement only

The original candidate, nets and SHA remain unchanged. Local scripts/ai_native_pilot_placement_geometry.py requires exact ST STM32F103C8T6 / LQFP-48 and Sensirion SHT31 identities and uses only the previously checked-in KiCad official pad geometries:

  • LQFP-48_7x7mm_P0.5mm, original digest: ec36273cf5fa99acf022c2f5af17310d123fa4b5ccfe98a2f562fedabe7f3f46
  • Sensirion_DFN-8-1EP_2.5x2.5mm_P0.5mm_EP1.1x1.7mm: 2380f3b4d6982902f05e8940603f19f7cfbc1bdfd6ae0f78ebd281c1a3f30a8f

Original part ID, pin numbering, 48/9 physical pad inventories and physical SHA are verified; any mismatches refuse the derived design. ST's STM32F103C8 datasheet DS5319 Rev 20 specifies LQFP48 7x7 mm: https://www.st.com/resource/en/datasheet/stm32f103c8.pdf

GCT USB4105 is placed at the provisional 100×80 mm PCB bottom edge. The vendored footprint's Dwgs.User board-edge line lies at relative Y=3.675 mm, so local J1 center is (50,76.325 mm). This is geometric alignment to a KiCad drawing marker only, not validated mating/connector envelope, shield mounting, fabrication or enclosure approval. Manufacturer drawing: https://gct.co/files/drawings/usb4105.pdf

Actual independent KiCad result

Artifacts in build/qa-041-vendor-footprints/placement-v1/. Against build/qa-040-native-placement/source-bound-final/:

  • 9 → 0 shorts.
  • 277 → 0 copper clearance violations.
  • 131 → 0 solder-mask bridge violations.
  • 445 → 16 other DRC findings total.
  • 42 → 43 unrouted connections (new placement, still 0 tracks/zones).

Remaining native DRC findings: 12 lib_footprint_mismatch, caused by the difference between local synthetic footprint instance metadata and project-local library templates; 4 hole_clearance at two GCT USB4105 anonymous mechanical alignment holes adjacent to electrical contact pads. Do not waive either set or alter genuine vendor drill geometry without reviewed authority. Five DRC checks are still ignored by baseline project defaults and require coverage review.

All 12 schematic↔PCB UUID paths, every physical pad net and four separate J1.S1 GND UUIDs must remain verified. Source candidate SHA is still 34b97dd4fba4034b4605998e27d5a3cb7a20c210f16f233be406c6f613c863df. This is only geometry/source compatibility evidence; SPICE remains NOT CHECKED, production approval FALSE and routing remains incomplete.

Next

Resolve the library/PCB instance mismatch with a single authoritative footprint, verify the four GCT drill clearances against original manufacturing drawings without any rule waivers, then run native KiCad DRC and validate J1 shell copper before proceeding with #35 routing.